225 amp mega fuse.

#296416

Post by 626 »

Just a quick pic of my mega fuse and holder. The wire is 1 gauge. The fuse is 225 amps. It sits on a bracket I fabricated. It protects the wire run where it passes through the firewall.

Each piece of equipment is also fused individually.

Image
User avatar
DixieEcho82
4 PILL USER
4 PILL USER
Posts: 49
Joined: Oct 26 2010, 06:13
Real Name: Greg
Radio: RCI, Galaxy, Uniden
Contact:

Re: 225 amp mega fuse.

#297432

Post by DixieEcho82 »

Very nice. Just curious, what model of vehicle is that?
User avatar
yankee
Mud-Duck Sr.
Mud-Duck Sr.
Posts: 7
Joined: Jun 10 2009, 17:15
Handle: Yankee
Real Name: Jim
Antenna: Dipole
Radio: Yaesu browning cobra and others
Contact:

Re: 225 amp mega fuse.

#297433

Post by yankee »

Looks lik a jeep. Maybe an older cj
User avatar
626
Donor
Donor
Posts: 1,158
Joined: Apr 04 2008, 00:28

Re: 225 amp mega fuse.

#297434

Post by 626 »

That is a 1991 Jeep Wrangler

Those fuse holders are really very cool. They function as a junction block as well, you can connect several pieces of equipment. I use it because I have a cable running through the firewall and anytime you have a junction like that its a good idea to protect it with a fuse. Keep in mind that the fuse protects the jeep from burning down. Not the equipment

For the record, its an older YJ and the body is really similar to a CJ7
User avatar
rv_camper
2 PILL USER
2 PILL USER
Posts: 15
Joined: Jan 19 2014, 17:02
Real Name: RV

Re: 225 amp mega fuse.

#352903

Post by rv_camper »

I like the fuse setup, but I'm a little concerned about the current carrying capacity of the wire.

According to my charts, the 225 amp fuse you have is oversized for the 1 gauge wire. Is it possible you're actually using 1/0 cable?

You're not going to be drawing a continuous 225 amps, so I really don't see an overload condition heating the wire significantly, but you may be getting unnecessary voltage drop across the wire depending on the length.
User avatar
'Doc

Re: 225 amp mega fuse.

#353569

Post by 'Doc »

If it were me, I think I'd use a slightly smaller fuse/breaker than 225 amps. The size of cable isn't an issue, it's as large as the starter cable so I would think it ought'a handle anything you are likely to have as an electrical accessory. I don't think you need to run out and change the size of that fuse! ...unless you are going to give it to me, naturally...
- 'Doc